The use of "blue fuel" for domestic needs has a significant drawback - the difficulty in implementing delivery and storage. This shortcoming was overcome thanks to the gas tank - the "vat" for hydrocarbon liquefied gas.
Arrangement of autonomous gasification is subject to a set of requirements and standards. First of all, it is necessary to evaluate the parameters of the site, to determine the distance from the gas tank to the apartment building, the nearest buildings and communications.
Site assessment: installation of a gas tank
The main gasification of remote villages is not yet completed, and many settlements are left without convenient "blue fuel". An alternative solution for centralized gas supply is the installation of a gas tank and the arrangement of an autonomous network.
Gas holder is a monolithic container for storing natural gas. Structurally, the tank is made in the form of a tank with a neck. In the upper part there are elements that control the pressure and remaining fuel.
Undoubtedly, the operation of any gas equipment carries a certain risk, therefore a number of requirements are imposed on the organization of autonomous gasification, the location and installation technology of a gas tank.
In a galgozero, liquefied gas is gradually converted into steam, the propane-butane composition enters the reactor and acquires the desired pressure. The Blue Fuel Pipeline is supplied to consumers
The gas storage installation site is evaluated according to the following criteria:
- relief;
- the composition of the underlying and surrounding ground layers and the proximity of groundwater;
- the presence of water points, residential, utility and public premises.
Relief. The area selected for surface mounting should be flat. This requirement is especially true when installing ground-based modifications - installation on a slope is prohibited.
Priming. It is permissible to place a gas storage in soil massifs with different moisture contents. The physical and mechanical properties of the rocks will determine the convenience of land work and the choice of type of gas tank.
If there is no risk of valve flooding, models without a high neck can be used. As an option, a tank is suitable where the bends are attached to the welded nozzles 12 cm long - this "safety" height, if there is any doubt about the flooding.
For places with "high" groundwater, constructions with an elongated neck have been developed that provide protection to the reinforcement. Due to the protection device, the operation of the gas tank is stable and efficient
Water is an excellent conductor of heat waves, and the process of evaporation of a propane-butane mixture determines the temperature of the medium. The higher the indicator, the more intense the process. Installation work in low-moisture rocks is simpler, but the environment for the normal operation of the gas tank is less favorable.
Coarse-grained soil can be dangerous, especially if its components are poorly rounded, i.e. with sharp edges. Boulders, pebbles and large rubble complicate the installation of equipment, and the mass of gravel and wood makes an additional load on the gas pipeline.
In most cases, a pit is developed for the installation of the selected gas tank, which is recommended to be filled with river or quarry sand after the structure is submerged.
Proximity to water intake. According to construction standards, the minimum distance from the gas tank to the reservoir (well, well) is 15 m, to the water main - 5 m.
Neighborhood with buildings. Fire distances from liquefied gas tanks to structures are indicated in clause 8.1.6 of the gas distribution systems normative document (SNiP 42-01-2002). The following section is devoted to this issue.
It is more practical to place the gas holder closer to the gate for an unhindered entrance of the gas carrier and to refuel the tank.
The platform above the gas storage is a kind of exclusion zone. It is forbidden to equip a place for a barbecue, install barbecues and other flammable equipment
In addition, concreting or paving of the site is unacceptable, as well as the organization of a parking space and tree planting.
Fire distances to objects to be protected
Determining the optimal location for installing a gas tank on a site depends on the volume of the tank and the method of installation: underground or surface installation. For each option, strict standards are defined, the neglect of which is unacceptable according to explosive, environmental and fire safety requirements.
Volume - the determining parameter of the remoteness of buildings
From the correct choice of volume depends not only the location of the tank on the site, but also ease of use. The volume of the gas holder is selected so that one refueling is enough for 1-1.5 years. Volume calculation is based on the area of the house.
According to the norms, 20 l of “blue fuel” is consumed per year for heating 1 square meter of housing. If the gas is used in parallel for cooking, hot water, the rate increases to 27 l / year.
Knowing the dimensions of the house and the needs of residents, it is easy to carry out the calculation. For example, for a cottage of 200 square meters, a gas tank with a volume of 4000 liters is suitable. An alternative is to determine the size of the tank by the power of the boiler plant. For example, for a 50 W boiler, a 5,000 liter gas holder is required.
It should be noted that the maximum filling of the gas storage is 85% of the total displacement, and the minimum remaining fuel is 5%. Therefore, when choosing a gas tank, a certain margin must be taken into account (plus 10-15%)
Norms of location of underground gas tanks
For year-round operation in cold winters, you must choose an underground "storage". The module plunges below the freezing line of the soil, which supports the natural evaporation of gas at sub-zero outside temperatures.
General standards for distance from underground tanks of any volume:
- sports grounds, children's complexes, garages - 10 m;
- underground pipeline for heating and sewage - 3.5 m;
- external communications not included in the backup equipment group - 5 m;
- edge of the carriageway of the non-high-speed road for 1-2 lanes - 5 m;
- motorways and express roads for 3 or more lanes - 10 m;
- access tram track, railways of industrial importance - 10 m.
The distance to buildings for various purposes is determined by the capacity of the tank for liquefied gas. Gradation of values is provided for "storages" of volume: up to 10 cubic meters, 10-20 cubic meters, 20-50 cubic meters.
The distance to residential buildings for monoblock containers is up to 10 cubic meters - 10 m, up to 20 cubic meters - 15 m, up to 50 cubic meters - 20 m. The distance of public facilities is 15, 20 and 30 m, respectively
Various standards are provided for the installation of a private "gas storage" in relation to production facilities. The range of distances is 8-15 m. The distance to general-purpose railways is also regulated - 20-30 m, depending on the volume of the gas tank.
SNiP allows a 50% reduction in the interval between a residential building and a "gas vat". However, such a decision must be justified by technical reasons and agreed upon at the local gas distribution system unit.
The distance should be counted from the nearest foundation point to the wall of the gas tank. This norm is not stipulated in regulatory documents, but is practiced when installing a gas storage
In addition to the requirements for the remoteness of the gas tank from different objects, a list of rules for adjusting the underground "storage" is provided:
- installation depth - at least 60 cm from the upper wall of the tank to the soil surface;
- distance between underground gas tanks - at least 1 m;
- the neck and fittings of the tank must remain freely accessible.
Regardless of the displacement, the underground tank is mounted on a foundation - a concrete slab. The base prevents the reservoir from “floating up” in the event of soil movements.
Subtleties of mounting a ground tank
The use of a ground gas tank has several significant advantages: simplicity, installation speed, and a decrease in the intensity of metal corrosion. Local damage is easy to detect and repair in a timely manner.
However, this type of equipment is rarely used for gas supply to a private house. The main reason is a significant decrease in system performance in winter. At sub-zero temperatures (below -0.5 ° C), liquefied gas does not evaporate naturally.
To support the process, a gas tank must be equipped with an evaporator. With a low consumption of “blue fuel”, capital investments in gasification pay off for a very long time. Due to ground-based location, the requirements for fire distances from the gas storage to buildings and other facilities are more stringent.
Minimum distances are given separately for three groups of sizes: up to 5 cubic meters, from 5 to 10 cubic meters and tanks with a capacity of 10-20 cubic meters. The “+” sign indicates the distance from the gas tank to real estate not serviced by the installation
Additional restrictions on the location of the ground "gas vat":
- general-purpose railways - 25-30-40 m in accordance with the volume;
- local tram and railway lines - 20 m;
- roads of IV-V category (1-2 lanes) - 10 m, I-III category (from 3 lanes) - 20 m.
For safety reasons, a kind of open hood is being arranged over the gas tank, protecting the module from direct sunlight and precipitation. Overheating of the tank or lightning can cause an explosion, and rain and snow can lead to accelerated corrosion.
Placement of mobile gas storages
The mini-gas tank is a spacious gas cylinder with a volume of up to 500 cubic meters, equipped with the necessary valves for safe operation: a gearbox, a level gauge and safety valves. The equipment is compact in size, for example, the parameters of a tank of 480 l are: length - 2 m, diameter - 60 cm.
With proper use of the mini-format gas tank, its service life is the same as that of a full-sized gas tank. The mini-model is stationary or mounted on a caravan, which ensures mobility of the gas storage.
Refueling a mobile tank is greatly simplified, as it becomes possible both at the location and at the gas station.
An important advantage of a mini-gas tank is the lack of strict requirements for its placement. Work on connecting the tank to the gas system of the house takes about two hours
According to SP 63.13330 of 2011, the minimum distance from the house to a small gas tank is permissible, namely, placement directly against the wall. Remoteness of equipment from other objects of protection is not specified.
Mini-gas holders are in demand to provide autonomous gasification of rooms with a relatively small or seasonal fuel consumption: country houses, cafe area heating, a hotel. The reservoir is often used as a backup source of gas in case of interruptions from the central gas main.
Set of requirements for laying a gas pipeline
Certain standardized standards are also presented for the arrangement of the gas pipeline going from the gas tank to the house. Gas is supplied to the room via an underground highway through the basement. Safety rules prohibit the entry of a gas pipeline into a house underground.
Scheme of input pipe line into the house. Designations: 1 - gas holder, 2 - concrete base plate, 3 - condenser collector, 4 - underground pipeline, 5 - basement input unit
General requirements for laying a gas pipeline on the gas holder-house section:
- track depth - not less than 1.7 m;
- the width of the trench - there are no strict restrictions, the size depends on the meter of the gas pipeline and the quality of the soil
- the minimum slope towards the condensate collector is 1 cm per 1 m (not more than 5 °), the maximum deviation is 100 mm;
- distance from the highway to the foundations of buildings - 2 m or more;
- the distance to parallel communications is 1 m, with a cross arrangement - 2 m in height.
The underground line of the gas pipeline is mounted from high density polyethylene pipes containing nitrile. Ground highway - steel gas pipes. The polymer pipeline should not reach the point where the temperature of the soil drops to -20 ° C or less.
The transition of the polyethylene-steel gas pipeline is carried out at a depth of 40 cm. The site must be protected from electrochemical corrosion - a polymer coating is used to a height above the ground
Gas tank operating safety
Despite all the advantages of autonomous gasification, many consumers are frightened by the idea of the risks of storing flammable substances in the area near the apartment building.
To ensure safety, it is not enough to maintain the required distances during installation; all conditions for refueling, operation and maintenance of the gas holder installation must be observed.
Operating Rules:
- Inexhaustible reserve conservation - about ¼ of the volume. When using all the fuel in the tank, a vacuum is formed, with further refueling in violation of the technology, an explosion is possible.
- Filling a gas tank with an exclusively specialized company. Insignificant savings on the services of unskilled "gas workers" can lead to a fire.
- Safety valve operation monitoring. Timely troubleshooting will prevent an emergency.
- Prevent gas leakage. The outflow of “blue fuel” is the most dangerous - the propane-butane mixture “spreads” downward, since it is heavier than air.
The probability of fuel leakage occurs when the tank is damaged, valves fail, unqualified repair or refueling, and also when the elements of the gas distribution system are leaky.
The operation and fueling safety is ensured by the equipment: 1 - discharge of residues from the condenser collector, 2 - pressure relief valve, 3 - pressure reducer, 4 - gas pipeline, 5 - level gauge - measurement of tank fullness, 6 - gas valve, 7 - gas vapor extraction valve, 8 - manometer, 9 - liquid gas selection valve
Mandatory precautions include the use of lightning protection and grounding. Near the gas tank it is unacceptable to conduct welding work, kindling a fire.
The following article will familiarize you with standard rates for the installation of a gas tank, in which all items of upcoming expenses are analyzed in detail and recommendations are given on possible savings.
Video report on the work of the installed gas tank for servicing a private house. The review deals with the equipment snap-in ensuring safety of use, and the permissible distances to objects on the site:
One of the main requirements for the safe operation of the gas tank is compliance with the normalized distances from the apartment building and other facilities to the gas storage. Under unsatisfied conditions of the site itself, some leniency with respect to boundary distances is permissible. Assessment of the installation site and installation is best entrusted to a specialized company.
Tell us about how you selected a place on a personal site for installing a gas tank. It is possible that you have useful information that is useful to site visitors. Please write comments in the block below, post a photo on the topic of the article, ask questions.